We are pleased to introduce a hybrid boiler for industrial applications, which is a combination of a standard fire tube boiler and electric flange heaters.

  • Performance range: 1.2 - 8.4 t/h

  • H2 Readiness

  • Reduction of flue gas emissions

  • Optimized startup process

Your local Viessmann sales partner will provide you with individual advice.

Hybrid steam boiler

Capacity: 1.2 - 8.4 t/h | ~ 0.8 - 5.6 MW (higher capacity and pressure on request)

Fuel to electricity combustion ratio

Approximately 4:1

Optimized startup process

Thanks to the use of electricity

H2 Readiness

Ensures proportional use of hydrogen

Compensation of load peaks and expansion of the normal range

Provide more efficient management in case of partial load reduction

Reduction of flue gas emissions

From COx or NOx

Higher efficiency

Compared to models that run solely on fossil fuels

Reducing the use of fossil fuels

This reduces overall operating costs.

High reliability of supply

If fossil fuels fail

Rapid availability of thermal energy

By retaining electrical heat

Easy heat retention

In this way, unnecessary cycling of the burner can be avoided.

Media image

Vitomax HS-EH, high supply reliability thanks to the use of electric flange heaters

The new Viessmann Vitomax HS-EH hybrid boiler combines a proven fire-tube boiler with an additional electric flange heater.

Generating electric steam with this hybrid boiler offers numerous advantages. The focus is on clean, energy-efficient power supply. Equally important is high operational reliability and availability. Uninterrupted operation is guaranteed. We offer components designed to work together, providing cost-effective and future-proof system solutions for industrial applications.

What are the characteristics of the Vitomax HS-EH hybrid boiler?

These hybrid boilers use excess electricity to generate steam, thereby reducing the use of traditional fuels. This ensures not only increased climate safety but also operational reliability and cost savings.

The Viessmann Vitomax HS-EH hybrid boiler has a higher efficiency than similar models that use only fossil fuels. This allows for savings on fossil fuels, reducing overall operating costs and conserving valuable, limited resources. Operating costs are reduced primarily because the hybrid boiler uses inexpensive electricity. This can be nighttime electricity or excess electricity generated by the boiler itself. The use of electricity to generate steam also reduces carbon oxide and nitrogen oxide (COx and NOx) emissions in flue gases. This, in turn, means the company has to pay lower emissions taxes. Another advantage of using electricity is the high reliability of the power supply. If fossil fuels fail, the hybrid boiler can compensate proportionally. Thus, interruptions in industrial processes can be minimized.

The startup process can be optimized by using electrical energy. This prevents the flue gas temperature from dropping below the dew point. Once operating, the boiler switches to either the primary fuel or the secondary fuel. This means that fuels with a low flue gas dew point or whose condensate components would be harmful can also be used. Like all Viessmann fire-tube boilers, the Vitomax HS-EH hybrid boilers are H2- ready and allow proportional use of hydrogen.

Furthermore, the use of hybrid boilers allows for peak load balancing. The normal load range also increases, meaning that a better supply can be ensured during partial load reductions.

Finally, electric heat storage offers several advantages during use. It not only provides rapid heat generation but also eliminates unnecessary burner cycles. This, in turn, reduces wear and tear, thereby saving costs.

Electricity consumption in a hybrid boiler

To ensure efficient energy use, the Vitomax HS-EH hybrid boiler is equipped with up to two heating cartridges. These “flanged heaters” are connected to the boiler via a connector. They are highly resistant to corrosion and mechanical stress. Depending on the model, the heating cartridges can be inserted up to 4.5 meters.

Media image

Significance for the energy transition

By choosing a Viessmann hybrid boiler, you’ll be contributing to the energy transition. This system utilizes the “electricity to heat” principle, using electricity to generate steam. This allows surplus electricity generated internally or peaks in grid power to be used in an environmentally and economically efficient manner. This reduces the use of fossil fuels. Wind and solar power are emissions-free. A hybrid boiler thus allows you to adopt a more environmentally friendly and sustainable approach. It’s also another step toward keeping global warming within the 1.5 degrees Celsius limit set by the Paris Agreement.

Request a quote for the Vitomax HS-EH hybrid boiler

The Viessmann hybrid boiler can be used for steam production. Our specialists will be happy to assist you with your projects. If you have any further questions, please feel free to request a personal consultation with a specialist. Our experts will review your project requirements with you to determine the feasibility.

Your consultation with an expert

Our specialists will be happy to help and support you in your projects.